SewerTest Lite
SewerTest Lite® is equipped with the last ARM Cortex A8 CPU. In other words, this embedded system is designed for low consumption, military environment and data integrity is ensured by a stable operating system Windows CE 6.0. Software and data are directly saved on the motherboard flash memory (512Mb). If the SewerTest Lite® is switched during starting or shutdown, it's not a problem it uses e a real embedded environment!
![]() |
The battery technology is without lead acid for numerous reasons: RoHs standard, weight loss, higher operating temperature range ... This new type of technology offers a very good shelf life and capacity. You can work without charging during more than 8 hours. In case of battery shutdown, SewerTest Lite® is delivered with a 5m cable with car connector. |
Embedded pressure sensor 0-300mbar uses a complex signal processing to ensure a maximum reliability and accuracy (0,05 %FS). If you need high pressure test, SewerTest Lite ® is equipped with an input connector able to receive externals sensors (option).
Very easy to use, just describe your test (diameter, length, material ...) and press start! SewerTest Lite® software indicates step by step, all the instructions for the operator.
Technical informations
Operating temperature |
|
SewerTest Office Software
SewerTest Office ® is delivered with each SewerDev product buyed. You can install this software each time you need in your company.
With this software, it's easy to import test data from USB flash key. You can organize your test, modify some informations (name of manhole for exemple, lenght ...), modify/add/delete connexion, add a comment for each test.
If you want to prepare the job of your operator before, you can create from office a complet project with all informations. In each SewerDev product you can import a project file to start each prepared tests.
Organize you test to have a clear report. This report is composed with 3 types of page :
Welcome page describing quickly customer information; including a table with all linear length, anomaly ...; a general comment; Signatures
Table page resuming quickly all test and result (green for a conform test, red for other result)
Each test with complet information, material serial number, certificate date, GPS coordonate (if you have GPS Device option), graphic, comment ...
Operating system
Windows 2000, XP, Vista, Seven (32bits only)
Print option
2 logo, footer of page
![]() |
![]() |
Click to enlarge